Battery
deep cycle battery,12V, 38Ah
Manufactured by Concorde Battery Corporation
Description of Solar Battery:

VRLA-AGM Deep Cycle Battery for Off Grid and Grid
Tied Systems.

Sun Xtender batteries provide safe, reliable and
long lasting power. Environmentally friendly, there
is no exposed lead on Sun Xtender batteries and
they are 100 percent recyclable. Sustainable,
Clean, Renewable Energy Storage.
PVX-420T Sun Xtender, sealed AGM
deep cycle battery,12V, 45Ah

PVX-420T Solar Battery

Manufactured by Concorde Battery Corporation
Description of Solar Battery:

Sun Xtender pioneered renewable energy storage
batteries for Off Grid and Grid Tied Solar and Wind
Systems as well as back up power for essential
appliances and machines such as cash registers,
computers, and telephony. PVX-420T is a deep
cycle battery with AGM construction.
PVX-490T Sun Xtender, sealed
AGM deep cycle battery,12V, 55Ah

Manufactured by Concorde Battery Corporation
Description of Solar Battery:

VRLA-AGM Deep Cycle Battery for Off Grid and
Grid Tied Systems.

Sun Xtender batteries provide safe, reliable and
long lasting power. Environmentally friendly, there
is no exposed lead on Sun Xtender batteries and
they are 100 percent recyclable. Sustainable,
Clean, Renewable Energy Storag
Shipping charge to 48 continental US states only, NOT IN Puerto Rico , Hawaii, Alaska, Virgin Islands.
We do not ship to APO or PO Box addresses.

FOR INTERNATIONAL ORDERS: All orders from outside the United States require a wire transfer. and clear Address for calculate the shipping cost Please contact us by
email for this information at sales@offgridusa.us

Since 1987, Sun Xtender solar batteries have been hand crafted for quality in the U.S.A. Valve regulated lead acid batteries with AGM construction (VRLA-AGM) is the
original AGM design adopted by the military. Non-spillable construction prohibits any electrolyte leaking or spewing, allowing the battery to be used upright or on its end or
side. The maintenance free AGM design means no water replenishment - ever. 
Copyright 2015 Off Grid USA. All rights reserved.
Web Hosting by Yahoo!
PVX-560T Sun Xtender, sealed AGM
deep cycle battery,12V, 63Ah 
Manufactured by Concorde Battery Corporation
Description of Solar Battery:

PVX-560T Solar Battery

Manufactured by Concorde Battery Corporation
Description of Solar Battery:

Recombinant gas Sun Xtender® Series solar
batteries are low resistance, valve regulated lead
acid (VRLA) batteries.
PVX-690T Sun Xtender, sealed AGM
deep cycle battery,12V, 79Ah

Manufactured by Concorde Battery Corporation
Description of Solar Battery:

PVX-690T Solar Battery

Manufactured by Concorde Battery Corporation
Description of Solar Battery:

Recombinant gas Sun Xtender® Series solar
batteries are low resistance, valve regulated lead
acid (VRLA) batteries. 
PVX-840T Sun Xtender, sealed
AGM deep cycle battery,12V, 96Ah

PVX-840T Solar Battery

Manufactured by Concorde Battery Corporation
Description of Solar Battery:

VRLA-AGM Deep Cycle Battery for Off Grid and
Grid Tied Systems.

Recombinant gas Sun Xtender® Series solar
batteries are low resistance, valve regulated lead
acid (VRLA) batteries. 
PVX-890T Sun Xtender, sealed AGM
deep cycle battery,12V, 102Ah  
PVX-890T Solar Battery

Manufactured by Concorde Battery Corporation
Description of Solar Battery:

VRLA-AGM Deep Cycle Battery for Off Grid and Grid
Tied Systems.

Recombinant gas Sun Xtender® Series solar
batteries are low resistance, valve regulated lead
acid (VRLA) batteries. 
PVX-1040T Sun Xtender, sealed
AGM deep cycle battery,12V, 120Ah
VRLA-AGM Deep Cycle Battery for Off Grid and Grid
Tied Systems.
PVX-1040T is a common 12 volt renewable energy
battery for solar, wind and back up energy storage.
Preferred for its compact 27 battery size and deep
cycling capacity, the PVX-1040T features clean,
sustainable, efficient operation. Since 1987, Sun
Xtender has been designing valve regulated lead
acid batteries with AGM construction (VRLA-AGM).
The non-spillable construction allows the battery
to be used upright or on its end or side and the
maintenance free AGM design means no water
replenishment ever. 
PVX-2580L Sun Xtender, sealed
AGM deep cycle battery,12V, 305Ah
PVX-3050T Solar BatteryManufactured by
Concorde Battery CorporationDescription of Solar
Battery:
VRLA-AGM Deep Cycle Battery for Off Grid and
Grid Tied Systems.
Sun Xtender batteries provide safe, reliable and
long lasting power.
Environmentally friendly, there is no exposed lead
on Sun Xtender batteries.
100 percent recyclable.
Sustainable, Clean, Renewable Energy Storage.
$317.00
$248.50
$317.00
$225.00
$270.00
$178.00
$124.32
$650.00
$373.00
$355.00
$479.00
$292.00
BATTERY RA12-110D ( 12V110Ah) /
SPECIFICATIONS 
Cells Per Unit 6
Voltage Per Unit 12
Capacity 110Ah@20hr-rate to 1.75V per cell @ 25°
C
Weight Approx. 30 Kg
Max. Discharger Current 1100 A (5 sec)
Internal Resistance Approx. 5 m Ὠ
Operating Temperature Range Discharge: -20°
C~60°C
Charge: 0°C~50°C
Storage: -20°C~60°C
Normal Operating Temperature Range 25°C ± 5°C
Float Charging Voltage 13.6 to 13.8 VDC/unit
Average at 25°C
Recommended Maximum Charging Current Limit
30 A
Equalization and Cycle Service 14.6 to 14.8
VDC/unit Average at 25°C
Self Discharge RITAR Valve Regulated Lead Acid
(VRLA) batteries can be
stored for more than 6 months at 25°C. Self-
discharge ratio
less than 3% per month at 25%C. Charge
batteries before using.
Terminal Terminal F5 / F12
Container Material A.B.S. (UL94-HB), Flammability
resistance
of UL94-V1 can be available upon request.
BATTERY RA12-200D ( 12V200Ah) /
SPECIFICATIONS
Cells Per Unit 6
Voltage Per Unit 12
Capacity 200Ah@20hr-rate to 1.75V per cell @ 25°
C
Weight Approx. 53 Kg
Max. Discharger Current 2000 A (5 sec)
Internal Resistance Approx. 4.0 m Ὠ
Operating Temperature Range Discharge: -20°
C~60°C
Charge: 0°C~50°C
Storage: -20°C~60°C
Normal Operating Temperature Range 25°C ± 5°C
Float Charging Voltage 13.6 to 13.8 VDC/unit
Average at 25°C
Recommended Maximum Charging Current Limit
54 A
Equalization and Cycle Service 14.6 to 14.8
VDC/unit Average at 25°C
Self Discharge RITAR Valve Regulated Lead Acid
(VRLA)
batteries can be stored for more than 6 months
at 25°C. Please charge batteries before using.
Terminal Terminal F12 / F16
resistance
of UL94-V1 can be available upon request.
BATTERY RA12-245D ( 12V245Ah) /
SPECIFICATIONS
Cells Per Unit 6
Voltage Per Unit 12
Capacity 245Ah@20hr-rate to 1.75V per cell @ 25°
C
Weight Approx. 69.0 Kg
Max. Discharger Current 2450 A (5 sec)
Internal Resistance Approx. 3 m Ὠ
Operating Temperature Range Discharge: -20°
C~60°C
Charge: 0°C~50°C
Storage: -20°C~60°C
Normal Operating Temperature Range 25°C ± 5°
C
Float Charging Voltage 13.6 to 13.8 VDC/unit
Average at 25°C
Recommended Maximum Charging Current Limit
69 A
Equalization and Cycle Service 14.6 to 14.8
VDC/unit Average at 25°C
Self Discharge RITAR Valve Regulated Lead Acid
(VRLA)
batteries can be stored for more than 6 months
at 25°C. Please charge batteries before using.
Terminal Terminal F12
Container Material A.B.S. (UL94-HB),
Flammability resistance
of UL94-V1 can be available upon request.